|
|
|
|
|
HAI C3 (Cellular Communication Center)
|
HAI Part Number: 70A00-1
Tech Sheet
Manual
|
|
|
The HAI C3 (Cellular Communications Center) is a wireless cellular communicator that allows phone calls to be made
over the GSM cellular network using the existing telephones in your home. The HAI C3
can be used when there is no land line in your home or if the land line is temporarily unavailable.
The HAI C3 is perfect for homeowners without land lines, vacation homes, and locations that need remote monitoring.
It works with any standard security panel, including HAI's Omni family of
home controllers, to communicate alarm conditions using the GSM cellular network
when the land line or cable phone service has been cut.
|
|
|
|
|
|
|
|
|
|
The HAI KNX Gateway allows Omni and Lumina controllers to communicate with and control KNX devices installed on the network. Lighting, temperature/energy management, and motors (window coverings, shades, shutters, etc.) are among the many KNX devices that can be controlled from an HAI interface or via controller programming.
For the Lumina Pro, Lumina, OmniPro II, Omni IIe, and Omni LTe home control systems.
|
|
|
|
|
Top of Page
|
|
Water Temp Sensor
|
HAI Part Number: 14A00-8
Manual
|
|
|
This temperature sensor is used to monitor the temperature of pools, spas, aquatic ponds, and greenhouses. The temperature sensing device is potted in a stainless steel probe. It is designed specifically to monitor water temperature from the return/source and then report that information back to an HAI Omni Family controller. Supplied with stainless steel mounting screws and waterproof connectors.
For the Lumina Pro, Lumina, OmniPro II, Omni IIe, and Omni LTe home control systems.
|
|
|
|
|
Top of Page
|
|
Extended Range Indoor/Outdoor Temp Sensor
|
HAI Part Number: 31A00-7
Manual
|
|
|
The Model 31A00-7 Indoor/Outdoor Temperature Sensor is used for sensing indoor or outdoor temperatures from -40 F to 120 F. It is coated with a sealant to withstand outdoor moisture and features a high accuracy temperature sensor that doesn't need calibration.
The temperature can be used to activate programs for controlling temperatures in attics, garages, greenhouses, basements, wine cellars, and coolers. The temperature can be displayed on the console or spoken over the telephone. It can also report, log, alert, or generate an alarm if the temperature reaches freeze conditions or if the temperature goes above the high set point or drops below the low set point programmed in the system.
This sensor cannot be connected to a zone on an Expansion Enclosure (i.e. Model 17A00) for temperature. Run a 4-conductor wire from the controller location to each Model 31A00-7.
For the Lumina Pro, Lumina, OmniPro II, Omni IIe, and Omni LTe home control systems.
|
|
|
|
|
Top of Page
|
|
Extended Range Indoor/Outdoor Temp & Humidity Sensor
|
HAI Part Number: 31A00-8
Manual
|
|
|
The 31A00-8 Indoor/Outdoor Temperature Sensor is used for sensing indoor or outdoor temperature from -40 F to 120 F. It is coated with a sealant to withstand outdoor moisture and features a high accuracy temperature sensor that doesn't need calibration. This sensor comes with a bracket for mounting.garages, greenhouses, basements, wine cellars, and coolers. The temperature can be displayed on the console or spoken over the telephone. It can also report, log, alert, or generate an alarm if the temperature reaches freeze conditions or if the temperature goes above the high set point or drops below the low set point programmed in the system.
The Model 31A00-8 also includes a Humidity Sensor that is used for reporting the outdoor or indoor relative humidity from 0 to 100 percent. High and low humidity limits can be set for taking action (i.e. turning on the bathroom vent fan, running a/c in de-humidification mode, turning on humidifier in heating mode, etc.) or reporting high or low humidity conditions in homes, greenhouses, wine cellars, coolers, humidors, etc. Controlling humidity is particularly helpful in combating the growth of mold in vulnerable areas of the home, such as bathrooms, basements, attics, etc.
This sensor cannot be connected to a zone on an Expansion Enclosure (i.e. Model 17A00) for temperature. Run a 4-conductor wire from the controller location to each Model 31A00-8.
For the Lumina Pro, Lumina, OmniPro II, Omni IIe, and Omni LTe home control systems.
|
|
|
|
|
Top of Page
|
|
PESM
|
HAI Part Number: 1101A
Manual
|
|
|
The PESM (Programmable Energy Saver Module) is used to override existing thermostats for set-back control. It also may be used for sensing and controlling other temperatures, such as attic fans, garage fans, greenhouses, basements, wine coolers, humidors, etc. It may also be used to control spa heaters with remote temperature sensor.
The PESM reports temperatures to the home control system, and has a low voltage relay and LED indicator for control. The PESM doubles as a freeze sensor, which can cause the controller to dial out in the event of a furnace failure.
For the Lumina Pro, Lumina, OmniPro II, Omni IIe, and Omni LTe home control systems.
|
|
|
|
|
|
|
|
|
|
16 Zone Hardwire Expander
|
HAI Part Number: 10A06-1
Manual
|
|
|
This module adds 16 fully configurable input zones to a Lumina, Lumina Pro, Omni LTe,
Omni IIe, or OmniPro II home control system system. The module comes with
mounting hardware and cable to attach to the controller. Terminals are provided
for 16 additional zones that can be programmed for burglary, fire, temperature or
auxiliary inputs.
Up to 2 modules can be installed on the Lumina, Lumina Pro, Omni LTe, Omni IIe, and
OmniPro II home control systems for an additional 32 zone inputs.
|
|
|
|
|
Top of Page
|
|
Lumina Pro / OmniPro II
Expansion Enclosure
|
HAI Part Number: 17A00-1
|
|
|
The Model 17A00-1 Expansion Enclosure adds sixteen voltage outputs for
control and sixteen inputs for additional security/fire zones,
auxiliary or temperature inputs.
The 17A00-1 can be mounted up to
1000 feet from the main controller and has its own power supply and
battery. It reduces wiring use in larger installations.
It is commonly used for sprinkler systems, control of pumps, motors,
remote control circuit breakers, and additional security/fire zones.
Up to four Expansion Enclosures can be used in conjunction with the HAI Lumina Pro, OmniPro,
or OmniPro II home control system. Optional Model 19A00-1 8-Relay Module and Model 10A07-1
4-Relay Module mount in the enclosure.
It comes with a lock set with two keys.
|
|
|
|
|
Top of Page
|
|
|
16 Zone / 16 Output
Expansion Board
|
HAI Part Number: 17A00-9
|
|
|
The Model 17A00-9 is a 16 input/16 output expansion board on a universal
mounting plate with accessory kit and instructions for
installation in structured wiring enclosures.
For use with a Lumina Pro or OmniPro II home control system.
|
|
|
|
|
Top of Page
|
|
Lumina Pro / OmniPro II
Expansion Board
|
HAI Part Number: 17A00-8
|
|
|
The Model 17A00-8 Expansion Board is the board only portion of the
Model 17A00-1 Expansion Enclosure.
It adds sixteen voltage outputs for
control and sixteen inputs for additional security/fire zones,
auxiliary or temperature inputs.
For use with an HAI Lumina Pro, OmniPro, or OmniPro II home control system.
|
|
|
|
|
Top of Page
|
|
|
4-Relay Module
|
HAI Part Number: 10A07-1
|
|
|
Relay Modules are used to convert HAI
voltage outputs to Form C relay contacts for
switching pumps, motors, commercial lighting, remote control
breakers, and sprinkler systems. This Relay Module provides 4
independent Form C Relays. Contacts rated 5 amps at 24 VDC. LED indicators show
which relays are energized. This model is supplied with foam adhesive mounting tape.
For the Lumina, Lumina Pro, Omni LTe, Omni IIe, or OmniPro II home control systems.
|
|
|
|
|
Top of Page
|
|
8-Relay Module
|
HAI Part Number: 19A00-1
|
|
|
Relay Modules are used to convert HAI
voltage outputs to Form C relay contacts for
switching pumps, motors, commercial lighting, remote control
breakers, and sprinkler systems. This Relay Module provides 8
independent Form C Relays.
Contacts rated 5 amps at 24 VDC. LED indicators show
which relays are energized. This model has mounting holes.
Mounts in Lumina Pro / OmniPro II 17A00-1 Expansion Enclosure.
|
|
|
|
|
Top of Page
|
|
Serial Interface Module
|
HAI Part Number: 10A17-1
Manual
|
|
|
RS-232/485 serial board, accessory kit, 20 pin cable, instructions.
For the Lumina, Lumina Pro, Omni LTe, Omni II, Omni IIe, or OmniPro II home control systems.
|
|
|
|
|
Top of Page
|
|
Telephone Access Kit
|
HAI Part Number: 44A01-1
|
|
|
RJ31X cord and jack to add telephone access to a Lumina or Lumina Pro
home control system.
|
|
|
|
|
Top of Page
|
|
|
12V 5 AH Battery
|
HAI Part Number: 44A02-1
|
|
|
Replacement Battery for Lumina and Lumina Pro home control systems.
|
|
|
|
|
Top of Page
|
|
|
24V 40 VA Transformer
|
HAI Part Number: 44A03-1
|
|
|
Replacement Transformer for Lumina and Lumina Pro home control systems.
|
|
|
|
|
Top of Page
|
|
Chip Upgrades
|
HAI Part Numbers: Various
|
|
|
EPROM chip upgrade with installation instructions as follows:
- Lumina Pro Upgrade Chip
(HAI Part Number 20A04-22UPG)
- Lumina Upgrade Chip
(HAI Part Number 20A04-21UPG)
|
|
|
|
|
Top of Page
|
|
Enclosure Lock
& 2 Keys
|
HAI Part Number: 21A06-1
|
|
|
Lock and two keys for an HAI enclosure.
|
|
|
|
|
|
|
|
|
Serial PC Cable
|
HAI Part Number: 21A05-2
|
|
|
This cable connects the built in serial port of a Lumina, Lumina Pro, Omni LTe,
Omni IIe, or OmniPro II home control system to personal computers for HAI Web-Link II,
HAI Windows PC Access, and other systems.
Cable is 7 feet long and has a DB-9F connector.
|
|
|
|
|
Top of Page
|
|
Serial Connectivity Adapter Kit
|
HAI Part Number: 36A05-4
|
|
|
The 36A05-4 Serial Connectivity Adapter Kit is a Modular to
DB-9M adapter and a 7-ft 4-conductor modular cable used to connect
Lumina, Lumina Pro, Omni LTe, Omni IIe, and OmniPro II modular serial ports to
DB-9F serial port on devices such as Lutron RadioRA, and Connectivity Partner
Audio Systems from NuVo, Proficient Audio Systems, Russound, SpeakerCraft, and
Xantech (Lumina Pro and OmniPro II only).
|
|
|
|
|
Top of Page
|
|
|
|
The UPB™ PIM to computer cable is used to connect the UPB™ PIM
(HAI Part Number 36A00-1) to a computer's standard DB-9 serial port for
use with HAI UPB™ UPStart configuration software.
|
|
|
|
|
|
|
|
|
|
Two-Way Voice Module
|
HAI Part Number: 10A11-1
Manual
|
|
|
The Model 10A11-1 Two-Way Audio/Voice Alarm Module allows two-way
communication with a central station after an alarm, paging and
listening from an on-premises or remote phone, annunciation of alarm
and zone by voice, and voice messaging (not available on
all systems).
After an audible alarm, the module allows the central station to
control the listen/talk mode. After a silent alarm, the module
allows listen in only.
The Two-Way Voice Module provides a line-level audio output that can be tied into an amplifier or whole home audio system, such as Hi-Fi by HAI, and a page output that is activated whenever the Two-Way Voice Board generates audio output.
The Two-Way Voice Module will allow someone to broadcast messages through the phone by picking it up and dialing #832.
Do not mount speakers, microphones, 28A00 modules, or 33A00-4 consoles near any device that may produce noise (fans,
air conditioning units, audio speakers, etc.).
Microphones should be connected with 24 AWG or larger, shielded twisted pair wire. Wire length should not exceed 100 feet.
Connect the cable shields and negative wires together at the Model 10A11-1, Rev B terminal block only.
Do not connect the shield on the microphone end. Additional microphones can be connected to each input in parallel.
Speakers should be connected with 18 AWG or larger, twisted pair wire. For wire runs that exceed 50 feet, use 16 AWG wire or
larger. Wire length should not exceed 100 feet.
Use with HAI Part Number 33A00-4 Omni Console with Built-In Speaker/Microphone,
33A00-20 Lumina Keypad with Built-In Speaker/Microphone, 28A00-1 Surface
Speaker Microphone, or 28A00-2 Flush Speaker Microphone.
The Model 10A11-1 may be used with Lumina, Lumina Pro, Omni LTe,
Omni IIe, OmniPro and OmniPro II home control systems.
|
|
|
|
|
Top of Page
|
|
Surface Speaker/Microphone Module
|
HAI Part Number: 28A00-1
Manual
|
|
|
The Model 28A00-1 is a speaker and microphone assembly that
allows two-way communication with a central station after an
alarm, paging and listening from an on-premises or remote phone,
annunciation of alarm and zone by voice, and voice messaging (not available on
all systems) when connected to a Two-Way Voice Module. It may be used outdoors in
weather protected areas.
Do not mount speakers, microphones, 28A00 modules, or 33A00-4 consoles near any device that may produce noise (fans,
air conditioning units, audio speakers, etc.).
Microphones should be connected with 24 AWG or larger, shielded twisted pair wire. Wire length should not exceed 100 feet.
Connect the cable shields and negative wires together at the Model 10A11-1, Rev B terminal block only.
Do not connect the shield on the microphone end. Additional microphones can be connected to each input in parallel.
Speakers should be connected with 18 AWG or larger, twisted pair wire. For wire runs that exceed 50 feet, use 16 AWG wire or
larger. Wire length should not exceed 100 feet.
Dimensions: 5 3/16" H x 5 3/16" W x 2 5/8 D
Requires Two-Way Voice Module (HAI Part Number 10A11-1).
Works with Lumina, Lumina Pro, Omni LTe, Omni IIe, or OmniPro II home control systems.
|
|
|
|
|
Top of Page
|
|
Flush Speaker/Microphone Module
|
HAI Part Number: 28A00-2
Manual
|
|
|
The Model 28A00-2 is a speaker and microphone assembly that
allows two-way communication with a central station after an
alarm, paging and listening from an on-premises or remote phone,
annunciation of alarm and zone by voice, and voice messaging (not available on
all systems) when connected to a Two-Way Voice Module. It may be used outdoors in
weather protected areas.
Do not mount speakers, microphones, 28A00 modules, or 33A00-4 consoles near any device that may produce noise (fans,
air conditioning units, audio speakers, etc.).
Microphones should be connected with 24 AWG or larger, shielded twisted pair wire. Wire length should not exceed 100 feet.
Connect the cable shields and negative wires together at the Model 10A11-1, Rev B terminal block only.
Do not connect the shield on the microphone end. Additional microphones can be connected to each input in parallel.
Speakers should be connected with 18 AWG or larger, twisted pair wire. For wire runs that exceed 50 feet, use 16 AWG wire or
larger. Wire length should not exceed 100 feet.
Dimensions: 4 1/2" H x 4 1/2" W x 1 1/2" D (Protrudes only 1/2" when flush mounted)
Requires Two-Way Voice Module (HAI Part Number 10A11-1).
Works with Lumina, Lumina Pro, Omni LTe, Omni IIe, or OmniPro II home control systems.
|
|
|
|
|
|
|
|
|
Universal Mounting Plate
|
HAI Part Number: 20A07-2
|
|
|
Mounting plate, hardware kit & instructions. Used
to mount Omni family controllers, expanders, and
accessories in structured wiring enclosures.
For use with a Lumina, Lumina Pro, Omni LTe, Omni IIe, or OmniPro II home control system.
|
|
|
|
|
|
|
|
|
Lumina Demo Case
|
HAI Part Number: 18A00-4
|
|
|
Fully assembled and operational Lumina demo
system, including Lumina controller, RC-2000WH Omnistat2
thermostat, LCD keypad with built-in speaker, OmniTouch 5.7
Touchscreen, HAI Lighting Control: House Status Switch,
Scene Switch, Mode Switch, and Dimmer, UPB™
Powerline Interface Module and Phase Coupler. It is
packaged in a super duty black travel case. Demo
programs included.
|
|
| |
|
|
|
|
|
Demo Board Adapter Kit
|
HAI Part Number: 18A00-5
|
|
|
The Model 18A00-5 Demo Board Adapter Kit is a pre-wired circuit board that
plugs into the terminal sockets on a Lumina, Lumina Pro, Omni LTe, Omni IIe, or OmniPro II home control system. It is
used in HAI Demo Systems and now may be used by dealers or builders for showroom displays,
model homes, and other product demonstration applications.
Features include quick connect to console, thermostat, telephone, PC and 24 VAC
transformer plus phone line simulator, modular jacks for phone and console connections,
built in temperature sensor simulator, and two switched zones for security demonstration.
|
|
| |
|